Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy applications.
When used with specifically designed Film QA Pro™ software, Gafchromic™ film provides the most complete and accurate dosimetric measurement. Instant high- resolution images provide the high data integrity needed to increase confidence and peace of mind for both the physicist and the patient alike.
CK films are designed for patient and machine quality assurance for Cyberknife¹ machines. All CK cut films are available in both EBT3 and EBT-XD.
Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy applications.
When used with specifically designed Film QA Pro™ software, Gafchromic™ film provides the most complete and accurate dosimetric measurement. Instant high- resolution images provide the high data integrity needed to increase confidence and peace of mind for both the physicist and the patient alike.
CK films are designed for patient and machine quality assurance for Cyberknife¹ machines. All CK cut films are available in both EBT3 and EBT-XD.
Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy applications.
When used with specifically designed Film QA Pro™ software, Gafchromic™ film provides the most complete and accurate dosimetric measurement. Instant high- resolution images provide the high data integrity needed to increase confidence and peace of mind for both the physicist and the patient alike.
EBT-XD films are an extended dose film designed for patient quality assurance including, but not limited to, SRS, SRBT, small-field dosimetry, and hypofractionated treatments.
Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy applications.
When used with specifically designed Film QA Pro™ software, Gafchromic™ film provides the most complete and accurate dosimetric measurement. Instant high- resolution images provide the high data integrity needed to increase confidence and peace of mind for both the physicist and the patient alike.
EBT3 films are designed for machine quality assurance in preparation for patient treatment planning including, but not limited to, IMRT, VMAT, brachytherapy, Star Shot test, Picket Fence test, and Flatness and Symmetry test.
Dose Range: 0.1 Gy – 10 Gy
Energy Range: 100 KeV into the MV range
Product Code
Product
Format
828204
EBT3-810
8”x10”, 25 sheets per box
828206
EBT3-1417
12.8”x17”, 10 sheets per box
841975
EBT3P*
8”x10”, 25 sheets per box
*Gafchromic™ EBT3P is designed to fit Gafchromic™ Quick Phantom for End-to-End Testing
Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy applications.
Combined with Film QA Pro™ software, the best interpreter of Gafchromic™ film, the film provides the most complete and accurate dosimetric measurement. Instant high- resolution images ensures the data integrity needed to increase confidence and peace of mind for both the physicist and the patient alike.
EBT4 film with its exceptional dosimetry performance in the dose range of from 0.2 to 10 Gy is suitable for many applications including, but not limited to, IMRT, VMAT and brachytherapy.
The Gafchromic™ quick phantom™ device was designed for fast and accurate end-to-end testing for patient treatment verification. Gafchromic™ EBT3P film is customized EBT3 film for use in the quick phantom™ device. The EBT3P film has holes in the film that correspond to the pins in the quick phantom™ device to prevent film movement and provides automated registration. The quick phantom™ device offers unprecedented speed, convenience and accuracy for Radiation Therapy QA procedures using radio chromic films.
quick phantom™ device features:
body- two slabs of Plastic Water water-equivalent to within 1% from 160 keV to 25 MeV dimensions: 29 x 32 x 5 cm3
positioning –with a standard two-pin indexing bar the groove located on the bottom of the quick phantom™ device, it provides quick, accurate and repeatable positioning of the device on both CT and treatment couches
film position is indexed to the treatment couch allowing the comparison of the dose measurements to the treatment plan to be regarded as true end-to-end QA test of the treatment system
asymmetric features and fiducial patterning for correct orientation recognition in TPS
film positioning pins – The asymmetric placement of two film registration pins in the quick phantom™ device corresponds with the two-hole pattern on Gafchromic™ EBT3P film means there is only one possible orientation for the film in the phantom
FilmQA Pro™ software has a unique feature that recognizes the fiducial pattern on the film image and automatically aligns it with the treatment plan for quick and accurate analysis and facilitates end-to-end QA test of the treatment system
The quick phantom™ device is also available with an optional 2 cm thick slab of Plastic Water for pin-point Ion Chamber insertion
this slab is cut to lock to center while sandwiching the film. Available for A14, A1SL, and 31016 ion chamber
Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy applications.
RTQA2 films are designed for radiotherapy machine quality assurance including, but not limited to, light field alignment tests, radiation field alignment tests, Star Shot test, Picket Fence test, Flatness and Symmetry test, and position verification for high dose rate brachytherapy.