Contact
Industrial
Physics
Radiotherapy
Radiology
Ultrasound
Home

STS Thermo CM11 Clothing Monitor

cm11_750x500
  The STS CM11 simulator is a fully functioning real Thermo CM11 that has been modified for use in nuclear contamination training. The unit retains its full range of functions but has additional electronics inside the meter and operates with a simulated STS BP19/DP11 style probe. The monitor which ...Read more



  • Description
  • Specifications

 

The STS CM11 simulator is a fully functioning real Thermo CM11 that has been modified for use in nuclear contamination training. The unit retains its full range of functions but has additional electronics inside the meter and operates with a simulated STS BP19/DP11 style probe.

The monitor which is used for verification of decontamination and identification of contaminated hands and clothing is supplied with a 1.5m cable enabling easy frisking of potentially contaminated workers.  The system operates exactly as other STS systems using a clear odourless spray applied to represent the radioactive contamination and a gas detection system built into the probe.  The liquid spray is easily cross contaminated so that realistic training can be given on de-robing and decontamination exercises.

The harmless and non toxic simulant produces only a small vapour cloud which forces trainees to practice monitoring slowly and close to the surface to detect the liquid.  This also highlights the issues of contaminating the probe if it is dragged across a surface where the simulant has been applied and will now show signs of contamination when not directly monitoring.

The CM11 is designed to be wall or trolley mounted as suits the training environment.

PLEASE NOTE THESE UNITS ARE NOW ONLY AVAILABLE IF THE END USER CAN PROVIDE A UNIT FOR MODIFICATION -  PLEASE ALSO SEE THE STS CONTAMINATION MONITOR SIMULATOR AS AN ALTERNATIVE UPGRADE .

 

 

Dimensions 300 x 500 x 150 mm    
Weight 6.0 kg    
Construction Steel and plastic casing    
Display Type LCD    
Backlight  Yes    
Battery Powered from mains supply at 110 or 240V    
Detector STS gas detectors situated behind perforated face 
plate
   
Audio Output Selectable on Instrument    
Alarm Thresholds Selectable on Instrument    
Retained Functionality Original instrument controls & switches retained  Software unchanged from real instrument  
Connector Standard STS 5 pin connector to probe    
Operating & Storage Temperature Operating temp 0° C to +30° C  Above 30° C the stimulant will rapidly evaporate Storage temp -10° C to +40° C
Warm up time 30 seconds from switch on to ready    
Available Probes DP6, DP11    
Available Simulants LS1 –liquid stimulant spray SS4 – solid stimulant source