Endorectal MRI Coils

ecoils_600x600


MR Coils and Balloons

The MEDRAD® Prostate eCoil offers significantly higher signal-to-noise ratio (SNR) compared to surface coils and provides the sensitivity needed for effective use of post-processing software used in spectroscopy, especially at 3.0 T. The small field of view (FOV) and high spatial resolution enabled by endorectal coils provides clear images that can assist with diagnosis and treatment planning for diseases of the prostate and surrounding anatomy. It’s available for select MR scanners from GE® *, Philips® **, and Siemens® *** in both 1.5 T and 3.0 T in Canada and most countries in the European Union, Japan, and Australia.

*  GE is a registered trademark of General Electric Medical Systems, Inc. USA, Used by permission
**  Siemens is a registered trademark of Siemens A.G. Used by permission
***  Philips is a registered trademark of Philips Electronics N.V. Used by permission.

 

Patented Prostate eCoil technology

  • Enables close placement for more detail in a small FOV
  • Supports spectroscopy (MRIS/MRSI)
  • Assists with diagnosis and treatment planning

Prostate eCoil MRI Endorectal Coil

  • The small FOV and high spatial resolution images acquired with the Prostate Coil can assist the radiologist in improved sensitivity and specifically in the diagnosis and aid in treatment planning
  • Increases the signal-to-noise (SNR) and homogeneity
  • Supports multi-parametric imaging and sequences (Anatomical, Metabolic, Diffusion Weighted and Dynamic Contrast Enhancement Imaging)
  • The Prostate Coil probes are available in both 1.5T and 3.0T MRI scanners (GE, Siemens, and Philips only).

Cervix eCoil MR Endorectal Coil

  • The Cervix Coil for 1.5T MR provides visualization of the cervix and surrounding anatomy
  • Coil technology enables close placement for more detail in small FOV
  • Supports multi-parametric and spectroscopy imaging sequences
  • The Cervix Coil Probes are available at 1.5T for GE (for 8-ch 1.5T ID and 8-ch 3.0T ID) and Siemens MR scanners (for 1.5T ID for Magnetom Avanto, Magnetom Espree, Essenza, and 3.0T ID for TRIO TIM and Verio)

Colorectal eCoil MR Endorectal Coil

  • Visualization of the color and surrounding anatomy
  • Increases signal-to-noise (SNR) and homogeneity
  • Coil technology enables close placement
  • Supports multi-parametric and spectroscopy imaging sequences
  • The Colorectal Coil Probes are available at 1.5T for GE (for 8-ch 1.5T ID and 8-ch 3.0T ID) and Siemens MR scanners (for 1.5T ID for Magnetom Avanto, Magnetom Espree, Essenza, and 3.0T ID for TRIO TIM and Verio)

 

Downloads eCoil™ Brochure: Download PDF (1.87 MB)