TLD-100™ Thermoluminescent Dosimetry Material

tld_dosimeters_600x600



Deprecated: implode(): Passing glue string after array is deprecated. Swap the parameters in /home/clients/844ee2187cee70a16a19090345f717c4/web/medical-physics/plugins/content/jw_allvideos/jw_allvideos.php on line 73

Thermo Scientific™ TLD-100 Thermoluminescent Dosimetry Material consists of Lithium Fluoride (Li natural) LiF:Mg, Ti. Suitable for health and medical physics dosimetry applications.

Single element dosimeters and assemblies are widely used in many installations and processed using Harshaw TLD Systems. These systems include a range of readers and irradiators with compatible software to implement calibration, radiation evaluation and management, dose algorithms, health physics record keeping, finder database, glow curve analysis and chain of custody monitoring.

  • Nearly tissue-equivalent
  • ± 15% sample-to-sample uniformity
  • Repeatability to within 2% or better

Handling - Vacuum tweezers should always be used. (Avoid mechanical tweezers or fingers). Small scratches, loss of mass or foreign deposits affect light emission).

Annealing - For annealing temperatures up to 400°C, the containers should be made from high temperature stainless steel or oxidized aluminum, preferably thin to assist rapid cooling following annealing. (Do not use non-oxidized aluminum). The use of a dedicated annealing oven reduces the risk of contamination by foreign material. Place the annealing containers on open oven racks with air space all round to avoid inconsistent heat gradients. (Do not stack containers or allow them to touch the oven walls).

 
SPECIFICATIONS - TLD-100
Item Number SNP13015
Description TLD-100 Disk (Diameter: 3 × 0.38mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 3mm
Height (metric) 0.38mm
Accuracy ±15% (±2 sigma)
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/60CO
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO10106
Description TLD-100 Rod (Diameter: 1 x 6mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 1mm
Height (metric) 6mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO10111
Description TLD-100 Microcube (1 x 1 x 1mm)
Type Thermoluminescent Dosimetry Material
Width (metric) 1mm
Height (metric) 1mm
Length (metric) 1mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO18806
Description TLD-100 Chip (3.2 x 3.2 x 0.15mm)
Type Thermoluminescent Dosimetry Material
Width (metric) 3.2mm
Length (metric) 3.2mm
Height (metric) 0.15mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO18815
Description TLD-100 Chip (3.2 x 3.2 x 0.38mm)
Type Thermoluminescent Dosimetry Material
Length (metric) 3.2mm
Width (metric) 3.2mm
Height (metric) 0.38mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO18835
Description TLD-100 Chip (3.2 x 3.2 x 0.89mm)
Type Thermoluminescent Dosimetry Material
Length (metric) 3.2mm
Width (metric) 3.2mm
Height (metric) 0.89mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNP13610
Description TLD-100 Disk (Diameter: 3.6 x 0.25mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 3.6mm
Height (metric) 0.25mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNP13615
Description TLD-100 Disk (Diameter: 3.6 x 0.38mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 3.6mm
Height (metric) 0.38mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNP14524
Description TLD-100 Disk (Diameter: 4.5 x 0.6mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 4.5mm
Height (metric) 0.6mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNP14535
Description TLD-100 Disk (Diameter: 4.5 x 0.89mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 4.5mm
Height (metric) 0.89mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNP18835
Description TLD-100 Chip (Pelletized, 3.2 x 3.2 x 0.89mm)
Type Thermoluminescent Dosimetry Material
Length (metric) 3.2mm
Width (metric) 3.2mm
Height (metric) 0.89mm
Accuracy ±15 (±2 sigma) %
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/6°Co
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO10103
Description TLD-100 Rod (Diameter: 1 × 3mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 1.0mm
Height (metric) 3.0mm
Accuracy ±15% (±2 sigma)
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/60CO
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO10104
Description TLD-100 Rod (Diameter: 1 × 4mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 1.0mm
Height (metric) 4.0mm
Accuracy ±15% (±2 sigma)
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/60CO
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO14435
Description TLD-100 Chip (6.35 × 6.35 × 0.89mm)
Type Thermoluminescent Dosimetry Material
Length (metric) 6.35mm
Width (metric) 6.35mm
Height (metric) 0.89mm
Accuracy ±15% (±2 sigma)
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/60CO
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO10102
Description TLD-100 Rod (Diameter: 1 × 2mm)
Type Thermoluminescent Dosimetry Material
Diameter (metric) 1.0mm
Height (metric) 2.0mm
Accuracy ±15% (±2 sigma)
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/60CO
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy
   
Item Number SNO10116
Description TLD-100 Square Rod (1 × 1 × 6mm)
Type Thermoluminescent Dosimetry Material
Length (metric) 1.0mm
Width (metric) 1.0mm
Height (metric) 6.0mm
Accuracy ±15% (±2 sigma)
Emission Spectra 3500 to 6000Å (4000 maximum)
Energy Response 1.25 keV/60CO
Material Lithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity 1.0 at 60Co relative to LiF
Measurement Ranges 10pGy to 10Gy