  Versatile Stereotactic QA Ion chamber and film dose measurements in a water-equivalent phantom designed specifically for stereotactic radiosurgery and recommended by Accuray Film Dosimetry Measurements Five water equivalent Blue Water slabs allow film to be positioned 2 mm ...Read more



  • Description
  • Specifications

 

Versatile Stereotactic QA

Ion chamber and film dose measurements in a water-equivalent phantom designed specifically for stereotactic radiosurgery and recommended by Accuray

Film Dosimetry Measurements

Five water equivalent Blue Water slabs allow film to be positioned 2 mm apart for dose profile measurements of very small SRS targets. A cavity in each slab positions a 2.5 x 2.5 inch film in the exact center.

Ion Chamber Measurements

The 2 cm Blue Water ion chamber slab has an SDVP Plug with a cavity drilled to accommodate inter-changeable ion chamber plugs, and positions the detector in the exact center of the phantom to facilitate repositioning and fast, accurate measurements.

SRS Dosimetric QA Slab

For rigorous testing and evaluation of imaging, treatment planning, and dose conformity. The optional SRS Dosimetric QA Slab provides complex geometric targets to evaluate the imaging components of your treatment planning system. Five CT densities are available for a QA check of the CT density model.

 

SDVP Heterogeneity Insert

The optional SDVP Heterogeneity insert consists of two 5cm slabs, and a 2 cm chamber slab, each made of lung equivalent material. The lung-equivalent assembly is placed between the Stereotactic Dose Verification Phantom Blue Water Slabs. The Heterogeneity Insert Plug with gold fiducial markers is designed to simulate a small tumor within the lung-equivalent material.

Use the Exradin W1 Scintillator or other detector to perform small field tests in a highly heterogeneous environment. Included Extension Posts provide seamless integration with the Stereotactic Dose Verification Phantom for Monte Carlo dose verification.

 

 

Assembled Phantom Dimensions

  • Height 10.00 cm
  • Width 20.00 cm
  • Length 20.00 cm

 

Weight

  • Complete Stereotactic Dose Verification Phantom (ion chamber or film configuration) 4.4 kg
  • SRS Dosimetric QA Slab only 0.9 kg

 

Core Target Shape Volume

  • "Tentacle" Shape 9.86 cm3
  • "C" Shape 2.38 cm3
  • "Avoidance Structure" Shape 0.56 cm3

 

Fiducial Dimensions

  • Gold Markers Ø 0.8 x 5 mm long
  • Lead BBs Ø 1 mm