STS Contamination Monitor Simulator

contamination_monitor_simulator_750x500
  The Contamination monitor simulator is a wall mounted mains powered unit that replicates monitors such as the Thermo CM9/11. The system features a DP6 style frisking probe with an automatic background check and monitoring activated by removing the probe from the cradle. The unit features a full ...Read more



  • Description
  • Specifications

 

The Contamination monitor simulator is a wall mounted mains powered unit that replicates monitors such as the Thermo CM9/11.

The system features a DP6 style frisking probe with an automatic background check and monitoring activated by removing the probe from the cradle.

The unit features a full colour 7” touch screen with counts displayed and a bar graph visual indicator for both Alpha and Beta Channels. The meter is powered directly from a 240v or 110v mains supply via a wall plug.

The unit features a comprehensive menu system with user definable settings :

  • Apha Alarm
  • Beta Alarm
  • Display Units
  • Display Mode
  • Contamination Check
  • Monitoring Time
  • Background Monitoring Time
  • Changing Background Threshold
  • Operation in High Background
  • Background Substitution

The units respond to STS’s proprietary LS1 liquid simulant spray which may be used to show cross contamination and contamination clean-up.

The unit is supplied with a 12 month warranty and with no requirement for annual calibration or service the ongoing cost of ownership is minimal.

The case is powder coated steel with an integral wall mounting plate.  The probe hanger is included suitable for a DP6 probe only.

The probe connector is a 5 pin binder ensuring that the unit cannot be connected to a real probe.

The meter is supplied  with probe and cable, manual, charger and 1 can of LS1 simulant.

 

 

Dimensions 350 x 250 x 110 mm    
Weight 5.0 kg    
Construction Powder coated steel and Aluminium    
Display Type Full colour 7” TFT touch Screen    
Power Powered from mains supply at 110 or 240V    
Detector STS Gas detection system built into Probe    
Audio Output 1 Buzzer for Background 2nd buzzer for alarm status  
Functions Apha Alarm, Beta Alarm, Display Units 
Display Mode, Contamination Check 
Changing Background Threshold 
Monitoring Time 
Background Monitoring Time
Operation in High Background 
Background Substitution
Display Output Settable CPS/CPM    
Connector Standard STS 5 pin connector to probe    
Operating & Storage Temperature Operating temp 0° C to +30° C  Above 30° C the stimulant will rapidly evaporate Storage temp -10° C to +40° C
Warm up time 30 seconds from switch on to ready    
Available Probes DP6    
Available Simulants LS1 –liquid stimulant spray SS4 – solid stimulant source