Pro-CT Dose Phantoms
Radiology
Diagnomatic
Set of homogenous cylinders designed to image paediatric and adult head and body. Used for CTDI measurement and to separate dose information for each. When performing dose profile measurements, dose phantoms allow collecting information for the maximum, minimum and mid-range value of the nominal tomographic section thickness.
Benefits
Pro-CT Dose L (adult body)
150 mm thick homogenous PMMA cylinder
Diameter: 320 mm
Five Ø13.1 mm CT probe holes (one in the middle and 4 around the perimeter, 90° apart and 10 mm from the edge)
Pro-CT Dose M (adult head / paediatric body)
150 mm thick homogenous cylinder
Diameter: 160 mm
Five Ø13.1 mm CT probe holes (one in the middle and 4 around the perimeter, 90° apart and 10 mm from the edge)
Pro-CT Dose S (paediatric head)
150 mm thick homogenous cylinder
Diameter: 100 mm
Five Ø13.1 mm CT probe holes (one in the middle and 4 around the perimeter, 90° apart and 10 mm from the edge)
Additional Information
Engraved crosshair markings on phantoms for easier positioning
Acrylic rods for plugging all holes in the phantoms
Nested versions of the above phantoms are also available, where smaller cylinders can be inserted into larger ones together creating one solid cylinder
Carrying case, also with a trolley option
Product Features
Complies with:
- IEC 61223-3-5
- IEC 61223-2-6
- 21CFR 1020.33 specificationsCE certified
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Variants

Pro-CT Dose
04-203 - Pro-CT Dose Head and Body nested set - L and M phantoms with 9 plugs and a case with a trolley (matte finish)

Pro-CT Dose Adult and Paediatric
04-204 - Pro-CT Dose Adult and Paediatric nested set – L, M and S phantoms with 13 plugs and a case with a trolley (matte finish)
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld

Pro-CT Dose Phantoms
Radiology
Diagnomatic
Set of homogenous cylinders designed to image paediatric and adult head and body. Used for CTDI measurement and to separate dose information for each. When performing dose profile measurements, dose phantoms allow collecting information for the maximum, minimum and mid-range value of the nominal tomographic section thickness.
Benefits
Pro-CT Dose L (adult body)
150 mm thick homogenous PMMA cylinder
Diameter: 320 mm
Five Ø13.1 mm CT probe holes (one in the middle and 4 around the perimeter, 90° apart and 10 mm from the edge)
Pro-CT Dose M (adult head / paediatric body)
150 mm thick homogenous cylinder
Diameter: 160 mm
Five Ø13.1 mm CT probe holes (one in the middle and 4 around the perimeter, 90° apart and 10 mm from the edge)
Pro-CT Dose S (paediatric head)
150 mm thick homogenous cylinder
Diameter: 100 mm
Five Ø13.1 mm CT probe holes (one in the middle and 4 around the perimeter, 90° apart and 10 mm from the edge)
Additional Information
Engraved crosshair markings on phantoms for easier positioning
Acrylic rods for plugging all holes in the phantoms
Nested versions of the above phantoms are also available, where smaller cylinders can be inserted into larger ones together creating one solid cylinder
Carrying case, also with a trolley option
Product Features
Complies with:
- IEC 61223-3-5
- IEC 61223-2-6
- 21CFR 1020.33 specificationsCE certified
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Variants

Pro-CT Dose
04-203 - Pro-CT Dose Head and Body nested set - L and M phantoms with 9 plugs and a case with a trolley (matte finish)

Pro-CT Dose Adult and Paediatric
04-204 - Pro-CT Dose Adult and Paediatric nested set – L, M and S phantoms with 13 plugs and a case with a trolley (matte finish)