Benefits
Technical data:
Dimensions: 200 x 200 x 110 mm
Cover made of PMMA
Solid construction ensures durability and no leaks
Entrance wall made of milky / opaque 3 mm thick PMMA
Fixed measuring depth at 50 mm
Positioning markers on the top and side surfaces
Phantom can be filled with water through a seal plug - a funnel is provided to facilitate the process
Two elastic extension vessels compensate changes of the water volume caused by ambient temperature changes
Well fitted holders are available for different chamber types
Chamber holders can be interchanged (option)
Heavy duty carrying case
Product highlights:
Opaque / white entrance wall with crosshair, makes it very easy to accurately position the phantom in the beam
Side markers at the measurement depth provide further assistance during positioning
Interchangeable holders for different ionization chambers
Extremely well fitted holders are very thin at the reference point – 1 mm thick PMMA
Water-proof ion chamber holders are also available
Product features:
Complies with:
– IAEA Technical Reports Series No. 398
– IAEA Technical Reports Series No. 430
– IAEA Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems (IAEA-TECDOC-1540)CE certified
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld
Benefits
Technical data:
Dimensions: 200 x 200 x 110 mm
Cover made of PMMA
Solid construction ensures durability and no leaks
Entrance wall made of milky / opaque 3 mm thick PMMA
Fixed measuring depth at 50 mm
Positioning markers on the top and side surfaces
Phantom can be filled with water through a seal plug - a funnel is provided to facilitate the process
Two elastic extension vessels compensate changes of the water volume caused by ambient temperature changes
Well fitted holders are available for different chamber types
Chamber holders can be interchanged (option)
Heavy duty carrying case
Product highlights:
Opaque / white entrance wall with crosshair, makes it very easy to accurately position the phantom in the beam
Side markers at the measurement depth provide further assistance during positioning
Interchangeable holders for different ionization chambers
Extremely well fitted holders are very thin at the reference point – 1 mm thick PMMA
Water-proof ion chamber holders are also available
Product features:
Complies with:
– IAEA Technical Reports Series No. 398
– IAEA Technical Reports Series No. 430
– IAEA Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems (IAEA-TECDOC-1540)CE certified
The manual provides detailed guidelines for carrying out each test, results assessment and registration