Pro-MAM Gold – Meditron Switzerland

Pro-MAM Gold

Radiology

Diagnomatic

Contrast details mammography phantom according to European Protocol for quality assurance in Digital Mammography. It can be used to determine if mammographic images indicate objects with very low contrast and very small diameter, to find out the optimum exposure technique, or to compare image quality at various object thicknesses by varying the PMMA thickness.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

Product highlights:

  • Unmatched accuracy – up to 30 times better than other products on the market

  • Gold disc objects positioned as per EUREF specs

  • Objects’ diameter, thickness and layout can be modified according to individual specifications

  • no materials other than PMMA are used, so there is no need to calculate PMMA-equivalent attenuation for other materials such as aluminium

  • For full-field analog and digital units

  • Diagnomatic software provides automatic and semi-automatic analysis of phantom’s images, providing all the necessary information like Contrast-Details curve, making quality assurance simple and quick

‍Technical data:

  • Main PMMA module size: 240 x 180 x 20 mm

  • Main module contains gold (99.99%) discs organized in a 16 x 16 matrix (diameter x thickness) placed at a depth of 10 mm

  • One or multiple discs per cell configuration

  • Discs have the following standard diameters: 0.05, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.25, 1.5 and 2.0 mm

  • Discs have the following standard thicknesses: 30, 40, 50, 60, 70, 90, 120, 150, 200, 250, 350, 500, 700, 1000, 1700 and 2000 nm

  • Diameter accuracy 0.001 mm (1 μm)

  • Thickness accuracy: 0.1 nm (0.0001 μm)

  • 2 additional 240 x 180 x 10 mm PMMA plates

  • 2 additional 240 x 180 x 5 mm PMMA plates

  • Carrying case

‍Product features:

  • Complies with:
    – 4th edition of the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis (EPQC)
    – EUREF type test protocol version 1.2– IEC 61223-3-2
    – NHSBSP Equipment Report 0604, Commissioning and Routine Testing of Full Field Digital Mammography Systems Published April 2009 (Version 3)

  • CE marked

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-MAM Gold – Meditron Switzerland

Pro-MAM Gold

Radiology

Diagnomatic

Contrast details mammography phantom according to European Protocol for quality assurance in Digital Mammography. It can be used to determine if mammographic images indicate objects with very low contrast and very small diameter, to find out the optimum exposure technique, or to compare image quality at various object thicknesses by varying the PMMA thickness.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

Product highlights:

  • Unmatched accuracy – up to 30 times better than other products on the market

  • Gold disc objects positioned as per EUREF specs

  • Objects’ diameter, thickness and layout can be modified according to individual specifications

  • no materials other than PMMA are used, so there is no need to calculate PMMA-equivalent attenuation for other materials such as aluminium

  • For full-field analog and digital units

  • Diagnomatic software provides automatic and semi-automatic analysis of phantom’s images, providing all the necessary information like Contrast-Details curve, making quality assurance simple and quick

‍Technical data:

  • Main PMMA module size: 240 x 180 x 20 mm

  • Main module contains gold (99.99%) discs organized in a 16 x 16 matrix (diameter x thickness) placed at a depth of 10 mm

  • One or multiple discs per cell configuration

  • Discs have the following standard diameters: 0.05, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.25, 1.5 and 2.0 mm

  • Discs have the following standard thicknesses: 30, 40, 50, 60, 70, 90, 120, 150, 200, 250, 350, 500, 700, 1000, 1700 and 2000 nm

  • Diameter accuracy 0.001 mm (1 μm)

  • Thickness accuracy: 0.1 nm (0.0001 μm)

  • 2 additional 240 x 180 x 10 mm PMMA plates

  • 2 additional 240 x 180 x 5 mm PMMA plates

  • Carrying case

‍Product features:

  • Complies with:
    – 4th edition of the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis (EPQC)
    – EUREF type test protocol version 1.2– IEC 61223-3-2
    – NHSBSP Equipment Report 0604, Commissioning and Routine Testing of Full Field Digital Mammography Systems Published April 2009 (Version 3)

  • CE marked

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Franco Quaranta

Radiology

expert