Diagnomatic
The Image Quality Indicator (IQI) for CR scanners meets ASTM E2445/E2445M-20, ISO 16371-1, and EN 14784-1 standards. It allows accurate testing of spatial resolution, unsharpness, contrast, MTF, laser jitter, scanner slip, and shading, giving you reliable NDT results with consistent quality and efficiency.
Benefits
10-101 - version with one Pro-NDT DuplexWireIQI
10-103 - version with two Pro-NDT DuplexWireIQI
10-104 - version with two Pro-NDT DuplexWireIQI D15
Technical data:
Dimensions: 350 x 430 x 19 mm
Made of PMMA (Lucite)
T shaped brass target (laser beam jitter, MFT check, blooming / flare)
Pro-NDT DuplexWireIQI test object (basic spatial resolution, unsharpness)
BAM snail made of lead and low absorbent material (central beam alignment)
Two converging line pairs resolution patterns (Pro-Res MAM ConeType)
Three Ø19 x 0.3 mm (EL, EC, ER) measuring points (shading correction)
Cassette positioning locator
Homogeneous 0.5 mm Al strip (scanning slipping, shading)
Two cm / inch rulers (linearity check)
Three contrast sensitivity gauges made of Al, Cu and stainless steel with four holes of different depth
Calibration / test certificate according to ASTM E2445/E2445M-20, EN 14784-1 and ISO 16371-1
Product features:
Complies with:
– ASTM E2445/E2445M-20
– ISO 16371-1
– EN 14784-1CE marked (declaration of conformity according to ISO/IEC 17050-1)
The manual provides guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld

Pro-NDT CR
Radiology
Diagnomatic
The Image Quality Indicator (IQI) for CR scanners meets ASTM E2445/E2445M-20, ISO 16371-1, and EN 14784-1 standards. It allows accurate testing of spatial resolution, unsharpness, contrast, MTF, laser jitter, scanner slip, and shading, giving you reliable NDT results with consistent quality and efficiency.
Benefits
10-101 - version with one Pro-NDT DuplexWireIQI
10-103 - version with two Pro-NDT DuplexWireIQI
10-104 - version with two Pro-NDT DuplexWireIQI D15
Technical data:
Dimensions: 350 x 430 x 19 mm
Made of PMMA (Lucite)
T shaped brass target (laser beam jitter, MFT check, blooming / flare)
Pro-NDT DuplexWireIQI test object (basic spatial resolution, unsharpness)
BAM snail made of lead and low absorbent material (central beam alignment)
Two converging line pairs resolution patterns (Pro-Res MAM ConeType)
Three Ø19 x 0.3 mm (EL, EC, ER) measuring points (shading correction)
Cassette positioning locator
Homogeneous 0.5 mm Al strip (scanning slipping, shading)
Two cm / inch rulers (linearity check)
Three contrast sensitivity gauges made of Al, Cu and stainless steel with four holes of different depth
Calibration / test certificate according to ASTM E2445/E2445M-20, EN 14784-1 and ISO 16371-1
Product features:
Complies with:
– ASTM E2445/E2445M-20
– ISO 16371-1
– EN 14784-1CE marked (declaration of conformity according to ISO/IEC 17050-1)
The manual provides guidelines for carrying out each test, results assessment and registration