Pro-NM Linear Source Module

Radiology

Diagnomatic

This module can be used as a standalone in air or in water if mounted in the Pro-NM Performance cylinder. It can be used to evaluate changes of radius-of rotation on spatial resolution, spatial resolution measurement in air and in water, quantitative evaluation of reconstruction filters and scatter compensation methods.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

Technical data:

  • Insert diameter: 186 mm

  • Diameter of line sources: 1 mm

  • Spacing of line sources: 75 mm

  • Useful height of line sources: 70 mm

  • Stopcocks with luer connection allow for easy and safe filling and draining of line sources

Product features:

  • Complies with:
    - NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
    - AAPM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing
    - AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
    - ACR–SNM  (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-NM Linear Source Module – Meditron Switzerland

Pro-NM Linear Source Module

Radiology

Diagnomatic

This module can be used as a standalone in air or in water if mounted in the Pro-NM Performance cylinder. It can be used to evaluate changes of radius-of rotation on spatial resolution, spatial resolution measurement in air and in water, quantitative evaluation of reconstruction filters and scatter compensation methods.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

Technical data:

  • Insert diameter: 186 mm

  • Diameter of line sources: 1 mm

  • Spacing of line sources: 75 mm

  • Useful height of line sources: 70 mm

  • Stopcocks with luer connection allow for easy and safe filling and draining of line sources

Product features:

  • Complies with:
    - NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
    - AAPM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing
    - AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
    - ACR–SNM  (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Franco Quaranta

Radiology

expert