Pro-NM Performance SMALL – Meditron Switzerland

Pro-NM Performance SMALL

Radiology

Diagnomatic

The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

08-111 - standard version
08-112 - version with the PET Lid

Technical data:

Main cylinder

  • Inside cylinder diameter: 140 mm

  • Inside cylinder height: 150 mm

  • Cylinder wall thickness: 6 mm

Cold rods insert

  • Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm – height of rods: 40 mm

Cold spheres

  • Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm – height of the center of the spheres from the base plate: 78.5 mm

Optional PET Lid with cylindrical samples

  • Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm

  • PTFE solid cylinder diameter: 16 mm

  • Cylinder height: 25.4 mm

Accessories

  • Optional heavy duty carrying case (08-111-CS)

Product features:

  • Complies with:
    - NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
    - AAPM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing
    - AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
    - ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-NM Performance SMALL – Meditron Switzerland

Pro-NM Performance SMALL

Radiology

Diagnomatic

The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

08-111 - standard version
08-112 - version with the PET Lid

Technical data:

Main cylinder

  • Inside cylinder diameter: 140 mm

  • Inside cylinder height: 150 mm

  • Cylinder wall thickness: 6 mm

Cold rods insert

  • Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm – height of rods: 40 mm

Cold spheres

  • Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm – height of the center of the spheres from the base plate: 78.5 mm

Optional PET Lid with cylindrical samples

  • Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm

  • PTFE solid cylinder diameter: 16 mm

  • Cylinder height: 25.4 mm

Accessories

  • Optional heavy duty carrying case (08-111-CS)

Product features:

  • Complies with:
    - NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
    - AAPM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing
    - AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
    - ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration