Pro-NM ResL – Meditron Switzerland

Pro-NM ResL

Radiology

Diagnomatic

Pro-NM ResL for determination of resolution of Scintillation Cameras. The phantom offers precise determination of camera intrinsic resolution, collimator spatial resolution, field size and linearity.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

Apart from this standard size phantoms, we offer different sizes and configurations manufactured to the highest quality standards.

  • The most cost-effective means of performing routine quality control checks of gamma camera resolution or linearity on the market today

  • One image per detector head is all that’s needed to equally and effectively test all quadrants of the gamma camera

  • Perform routine quality control tests of spatial resolution and linearity in approximately one quarter of the time needed at present, which will make it possible to save time and money!

  • Quickly and easily perform extrinsic testing and intrinsic visual evaluation

  • Outperforms any 90° bar phantom, single-frequency Parallel-Line Equal-Space (PLES), Hine-Duley or orthogonal hole test pattern

  • Meet mandatory requirements of state quality control

  • Optimized for dual and triple-head gamma cameras

  • Ideal for large detectors. Its large size covers UFOV

  • Increase patient throughput

Technical data:

  • Dimensions: 447.2 mm (18”) x 609.6 mm (24”) x 15 mm (0,59”)

  • Dimensions: 533.2 mm (21”) x 533.2 mm (21”) x 15 mm (0,59”)

  • Lead bar widths: 6.35 mm (1/4"), 4.763 mm (3/16"), 3.969 mm (5/32"), 2.54 mm(1/10")

Product features:

  • Complies with:
    - NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
    - APM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing
    - AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
    - ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Variants

08-303 - 21’’ x 21’’ version

Dimensions: 533.2 mm (21”) x 533.2 mm (21”) x 15 mm (0,59”) Lead bar widths: 6.35 mm (1/4"), 4.763 mm (3/16"), 3.969 mm (5/32"), 2.54 mm(1/10")

08-305 - 24’’ x 18’’ version

Dimensions: 447.2 mm (18”) x 609.6 mm (24”) x 15 mm (0,59”) Lead bar widths: 6.35 mm (1/4"), 4.763 mm (3/16"), 3.969 mm (5/32"), 2.54 mm(1/10")

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-NM ResL – Meditron Switzerland

Pro-NM ResL

Radiology

Diagnomatic

Pro-NM ResL for determination of resolution of Scintillation Cameras. The phantom offers precise determination of camera intrinsic resolution, collimator spatial resolution, field size and linearity.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

Apart from this standard size phantoms, we offer different sizes and configurations manufactured to the highest quality standards.

  • The most cost-effective means of performing routine quality control checks of gamma camera resolution or linearity on the market today

  • One image per detector head is all that’s needed to equally and effectively test all quadrants of the gamma camera

  • Perform routine quality control tests of spatial resolution and linearity in approximately one quarter of the time needed at present, which will make it possible to save time and money!

  • Quickly and easily perform extrinsic testing and intrinsic visual evaluation

  • Outperforms any 90° bar phantom, single-frequency Parallel-Line Equal-Space (PLES), Hine-Duley or orthogonal hole test pattern

  • Meet mandatory requirements of state quality control

  • Optimized for dual and triple-head gamma cameras

  • Ideal for large detectors. Its large size covers UFOV

  • Increase patient throughput

Technical data:

  • Dimensions: 447.2 mm (18”) x 609.6 mm (24”) x 15 mm (0,59”)

  • Dimensions: 533.2 mm (21”) x 533.2 mm (21”) x 15 mm (0,59”)

  • Lead bar widths: 6.35 mm (1/4"), 4.763 mm (3/16"), 3.969 mm (5/32"), 2.54 mm(1/10")

Product features:

  • Complies with:
    - NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
    - APM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing
    - AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
    - ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Variants

08-303 - 21’’ x 21’’ version

Dimensions: 533.2 mm (21”) x 533.2 mm (21”) x 15 mm (0,59”) Lead bar widths: 6.35 mm (1/4"), 4.763 mm (3/16"), 3.969 mm (5/32"), 2.54 mm(1/10")

08-305 - 24’’ x 18’’ version

Dimensions: 447.2 mm (18”) x 609.6 mm (24”) x 15 mm (0,59”) Lead bar widths: 6.35 mm (1/4"), 4.763 mm (3/16"), 3.969 mm (5/32"), 2.54 mm(1/10")

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Franco Quaranta

Radiology

expert