Pro-RF AEC PMMA – Meditron Switzerland

Pro-RF AEC PMMA

Radiology

Diagnomatic

A set of acrylic plates for testing Automated Exposure Control of radiography equipment.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

02-201 - 240 x 240 mm, 20 cm stack version
02-221 - 300 x 300 mm, 20 cm stack version
02-221-15 - 300 x 300 mm, 15 cm stack version

Technical data:

  • Made of transparent PMMA

  • Optional 99.5% purity 240 x 240 x 25 mm aluminium plate (02-202)

  • Optional holder for stabilizing PMMA panels vertically

  • Optional carrying case

‍Available configurations:

  • Pro-RF AEC PMMA (02-201)- 240 x 240 mm (9x 20 mm, 1x 10 mm, 2x 5 mm)

  • Pro-RF AEC PMMA (02-221) - 300 x 300 mm (9x 20 mm, 1x 10 mm, 2x 5 mm)

  • Pro-RF AEC PMMA (02-221-15) - 300 x 300 mm (7x 20 mm, 1x 10 mm)

  • Thickness tolerance +/- 10%

  • Other sizes of filters upon request

‍Product features:

  • Complies with:
    – IEC 61223-3-1

  • CE marked

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-RF AEC PMMA – Meditron Switzerland

Pro-RF AEC PMMA

Radiology

Diagnomatic

A set of acrylic plates for testing Automated Exposure Control of radiography equipment.

Speak to an advisor

Franco Quaranta

Radiology

expert

Benefits

02-201 - 240 x 240 mm, 20 cm stack version
02-221 - 300 x 300 mm, 20 cm stack version
02-221-15 - 300 x 300 mm, 15 cm stack version

Technical data:

  • Made of transparent PMMA

  • Optional 99.5% purity 240 x 240 x 25 mm aluminium plate (02-202)

  • Optional holder for stabilizing PMMA panels vertically

  • Optional carrying case

‍Available configurations:

  • Pro-RF AEC PMMA (02-201)- 240 x 240 mm (9x 20 mm, 1x 10 mm, 2x 5 mm)

  • Pro-RF AEC PMMA (02-221) - 300 x 300 mm (9x 20 mm, 1x 10 mm, 2x 5 mm)

  • Pro-RF AEC PMMA (02-221-15) - 300 x 300 mm (7x 20 mm, 1x 10 mm)

  • Thickness tolerance +/- 10%

  • Other sizes of filters upon request

‍Product features:

  • Complies with:
    – IEC 61223-3-1

  • CE marked

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration