Pro-RF CDR
Radiology
Diagnomatic
The phantom for evaluation of imaging performance of radiographic systems. It allows wide-range low-contrast and high-contrastresolution evaluation and sensitometric measurements. Available in standard layout plus any custom configuration.
Benefits
Technical data:
Diameter: 180 mm
Thickness: 10 mm
3 circular rims on the outside of the phantom (Ø: 150, 160 and 170 mm) for geometry and collimation check
17 low-contrast objects, 11 mm in diameter, producing contrast values from 0.2 to 7.5%
17 small high-contrast objects, 0.5 mm in diameter, producing contrast values from 3.9 to 95.4%
10 sensitometric measurement point details, 5.6 in diameter, producing contrast values from 0.11 to 1.0
Pattern for line pair resolution evaluation (from 0.5 to 14.3 LP/mm)
1.0 and 0.5 mm high purity Cu attenuation filters (fits to the diaphragm housing)
Compact carrying case
Product features:
Complies with:
– IEC 61223-3-1
– IPEM Report 91 (2005): Recommended Standards for the Routine Performance Testing of Diagnostic X-Ray Imaging Systems published by the Institute of Physics and Engineering in MedicineCE marked
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld

Pro-RF CDR
Radiology
Diagnomatic
The phantom for evaluation of imaging performance of radiographic systems. It allows wide-range low-contrast and high-contrastresolution evaluation and sensitometric measurements. Available in standard layout plus any custom configuration.
Benefits
Technical data:
Diameter: 180 mm
Thickness: 10 mm
3 circular rims on the outside of the phantom (Ø: 150, 160 and 170 mm) for geometry and collimation check
17 low-contrast objects, 11 mm in diameter, producing contrast values from 0.2 to 7.5%
17 small high-contrast objects, 0.5 mm in diameter, producing contrast values from 3.9 to 95.4%
10 sensitometric measurement point details, 5.6 in diameter, producing contrast values from 0.11 to 1.0
Pattern for line pair resolution evaluation (from 0.5 to 14.3 LP/mm)
1.0 and 0.5 mm high purity Cu attenuation filters (fits to the diaphragm housing)
Compact carrying case
Product features:
Complies with:
– IEC 61223-3-1
– IPEM Report 91 (2005): Recommended Standards for the Routine Performance Testing of Diagnostic X-Ray Imaging Systems published by the Institute of Physics and Engineering in MedicineCE marked
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91