Pro-RT AlignCube
Radiotherapy
Diagnomatic
A versatile and easy-to-use tool for regular quality control of the geometric accuracy of the patient positioning systems. It enables the assessment of the alignment between the isocentre of the imaging system (CBCT, 2D kV, 2D MV) and the LINAC isocentre. Pro-RT Align-Cube phantom contains radiographic markers in an arrangement that allows evaluation of the translation and rotation of the phantom relative to the reference position. The marker material has been selected to ensure good visibility while avoiding artefacts which could compromise image registration. The position of the markers is clearly labelled on the phantom surface. Due to the additional markings of the offset position on the phantom surface, it is possible to quickly evaluate the accuracy of the automatic couch shift adjustment.
Benefits
It can be used to test:
Imaging systems (CBCT, 2D kV, 2D MV) and LINAC isocentre alignment
Automatic couch shift adjustment
Laser to isocentre coincidence
SGRT systems
Optical distance indicator accuracy
Technical data:
Dimensions 120 x 120 x 120 mm
Material: PMMA
Color: white
Central marker fi 8 mm
4 markers fi 6 mm in an asymmetric arrangement
External markings of the central and offset position
Markers for the light field evaluation
Carrying case
Product features:
CE certified
The Manual provides detailed guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld

Pro-RT AlignCube
Radiotherapy
Diagnomatic
A versatile and easy-to-use tool for regular quality control of the geometric accuracy of the patient positioning systems. It enables the assessment of the alignment between the isocentre of the imaging system (CBCT, 2D kV, 2D MV) and the LINAC isocentre. Pro-RT Align-Cube phantom contains radiographic markers in an arrangement that allows evaluation of the translation and rotation of the phantom relative to the reference position. The marker material has been selected to ensure good visibility while avoiding artefacts which could compromise image registration. The position of the markers is clearly labelled on the phantom surface. Due to the additional markings of the offset position on the phantom surface, it is possible to quickly evaluate the accuracy of the automatic couch shift adjustment.
Benefits
It can be used to test:
Imaging systems (CBCT, 2D kV, 2D MV) and LINAC isocentre alignment
Automatic couch shift adjustment
Laser to isocentre coincidence
SGRT systems
Optical distance indicator accuracy
Technical data:
Dimensions 120 x 120 x 120 mm
Material: PMMA
Color: white
Central marker fi 8 mm
4 markers fi 6 mm in an asymmetric arrangement
External markings of the central and offset position
Markers for the light field evaluation
Carrying case
Product features:
CE certified
The Manual provides detailed guidelines for carrying out each test, results assessment and registration