Pro-RT CTsim
Radiotherapy
Diagnomatic
This phantom is designed for quality control of a CT simulator, which usually consists of a CT scanner, virtual symulator software and a laser marking device (marking the centre of target volume). Since geometrical planning is the core of CT simulation, periodic quality control is essential for maintaining optimum image quality and patient care. The phantom allows performing detailed geometry and table movement tests as well as image quality assessment - low contrast resolution and high contrast detectability.
Benefits
Technical data:
Overall dimensions: 150 x 150 x 150 mm
Made of PMMA
Test object placed on four faces of the cube
Top face contains contrast details objects (CD), MTF, ray line divergence (RLD) and spatial linearity (SL) patterns
First side face contains MTF and spatial linearity (SL) patterns
Second and third side face contains ray line divergence (RLD) pattern
Optional carrying case
Product features:
Complies with:
– IEC 61223-3-5
– IEC 61223-2-6CE certified
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld

Pro-RT CTsim
Radiotherapy
Diagnomatic
This phantom is designed for quality control of a CT simulator, which usually consists of a CT scanner, virtual symulator software and a laser marking device (marking the centre of target volume). Since geometrical planning is the core of CT simulation, periodic quality control is essential for maintaining optimum image quality and patient care. The phantom allows performing detailed geometry and table movement tests as well as image quality assessment - low contrast resolution and high contrast detectability.
Benefits
Technical data:
Overall dimensions: 150 x 150 x 150 mm
Made of PMMA
Test object placed on four faces of the cube
Top face contains contrast details objects (CD), MTF, ray line divergence (RLD) and spatial linearity (SL) patterns
First side face contains MTF and spatial linearity (SL) patterns
Second and third side face contains ray line divergence (RLD) pattern
Optional carrying case
Product features:
Complies with:
– IEC 61223-3-5
– IEC 61223-2-6CE certified
The manual provides detailed guidelines for carrying out each test, results assessment and registration