Pro-RT ED – Meditron Switzerland

Pro-RT ED

Radiotherapy

Diagnomatic

The Pro-RT ED phantom is used to account for tissue heterogeneity in radiotherapy treatment planning. It can be used to define the precise correlation of CT data to the electron density of various tissues. The phantom consists of two nested disks that represent the head and abdomen. Nine different tissue equivalent electron density plugs can be positioned at 17 different locations within the scan field. Included is a water vial plug that can be filled with any fluid.

Speak to an advisor

Franco Quaranta

Radiotherapy

expert

Benefits

Technical data:

  • Electron Density Head Insert: Ø 180 mm x 50 mm

  • Electron Density Body without Head Insert: 330 mm x 270 mm x 50 mm

  • List of electron density plugs Ø 30 mm x 50 mm: Lung (inhale), Lung (exhale), Breast (50% gland / 50% adipose tissue), Fixed trabecular bone 200, Liver, Muscle, Adipose tissue, Fixed dense bone 800 , Fixed dense bone 1250, Water-filled plug and optional titanium, steel or aluminum core

  • Set of 2 Feet

  • Carrying case

Product features:

  • Complies with:
    - IEC 61223-3-5
    - IEC 61223-2-6
    - AAPM guidelines
    - ACR guidelines
    - 21CFR 1020.33 specifications

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-RT ED – Meditron Switzerland

Pro-RT ED

Radiotherapy

Diagnomatic

The Pro-RT ED phantom is used to account for tissue heterogeneity in radiotherapy treatment planning. It can be used to define the precise correlation of CT data to the electron density of various tissues. The phantom consists of two nested disks that represent the head and abdomen. Nine different tissue equivalent electron density plugs can be positioned at 17 different locations within the scan field. Included is a water vial plug that can be filled with any fluid.

Speak to an advisor

Franco Quaranta

Radiotherapy

expert

Benefits

Technical data:

  • Electron Density Head Insert: Ø 180 mm x 50 mm

  • Electron Density Body without Head Insert: 330 mm x 270 mm x 50 mm

  • List of electron density plugs Ø 30 mm x 50 mm: Lung (inhale), Lung (exhale), Breast (50% gland / 50% adipose tissue), Fixed trabecular bone 200, Liver, Muscle, Adipose tissue, Fixed dense bone 800 , Fixed dense bone 1250, Water-filled plug and optional titanium, steel or aluminum core

  • Set of 2 Feet

  • Carrying case

Product features:

  • Complies with:
    - IEC 61223-3-5
    - IEC 61223-2-6
    - AAPM guidelines
    - ACR guidelines
    - 21CFR 1020.33 specifications

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Franco Quaranta

Radiotherapy

expert