Pro-RT IsoBeam – Meditron Switzerland

Pro-RT IsoBeam

Radiotherapy

Diagnomatic

This is a multifunctional, precision quality assurance tool for daily, weekly or monthly quality assessments of all mechanical and geometrical treatment parameters of linear accelerators or teletherapy units. It is designed to easily and accurately check collimator isocentricity, gantry isocentricity, table isocentricity, collimator field size accuracy, radiation/light field congruence, isocenter rotational stability, ODI accuracy and laser light alignments.

Speak to an advisor

Franco Quaranta

Radiotherapy

expert

Benefits

Technical data:

  • Overall dimensions: 203 x 457 x 330 mm

  • Screen:
    – 305 x 305 mm
    – 2 opaque PMMA plates
    – Space for 25 x 30 cm film
    – Inscribed with lines precisely defining corners, edges, and centers of screen
    – Field sizes: 2 x 2 mm, 50 x 50 mm, 100 x 100 mm, 150 x 150 mm and 200 x 200 mm
    – Center lines scribed with short lines 10 mm apart
    – Tungsten markers 2 mm in diameter in the center and corners of the field
    – Can rotate 360° in 45° increments

  • Base with three leveling non-slip screws and bubble level

  • Optional off-the-table measurement possibility

Product features:

  • Complies with:
    – IAEA Technical Reports (Series No. 398)
    – IAEA Technical Reports (Series No. 430)
    – IAEA-TECDOC-1540, Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration

Let's Talk

Have a question, need a quote, or want to book a demo? We’re here to help.

info@meditron.ch

+41 22 995 01 91

Place de l'Industrie 2, 1180 Rolle

Schönenhofstrasse 19, 8500 Frauenfeld

Pro-RT IsoBeam – Meditron Switzerland

Pro-RT IsoBeam

Radiotherapy

Diagnomatic

This is a multifunctional, precision quality assurance tool for daily, weekly or monthly quality assessments of all mechanical and geometrical treatment parameters of linear accelerators or teletherapy units. It is designed to easily and accurately check collimator isocentricity, gantry isocentricity, table isocentricity, collimator field size accuracy, radiation/light field congruence, isocenter rotational stability, ODI accuracy and laser light alignments.

Speak to an advisor

Franco Quaranta

Radiotherapy

expert

Benefits

Technical data:

  • Overall dimensions: 203 x 457 x 330 mm

  • Screen:
    – 305 x 305 mm
    – 2 opaque PMMA plates
    – Space for 25 x 30 cm film
    – Inscribed with lines precisely defining corners, edges, and centers of screen
    – Field sizes: 2 x 2 mm, 50 x 50 mm, 100 x 100 mm, 150 x 150 mm and 200 x 200 mm
    – Center lines scribed with short lines 10 mm apart
    – Tungsten markers 2 mm in diameter in the center and corners of the field
    – Can rotate 360° in 45° increments

  • Base with three leveling non-slip screws and bubble level

  • Optional off-the-table measurement possibility

Product features:

  • Complies with:
    – IAEA Technical Reports (Series No. 398)
    – IAEA Technical Reports (Series No. 430)
    – IAEA-TECDOC-1540, Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems

  • CE certified

  • The manual provides detailed guidelines for carrying out each test, results assessment and registration