Pro-US MTF
Ultrasound
Diagnomatic
The tissue-mimicking phantom for use in routine technical quality assurance (TQA). The PVA based material mimics the sound velocity and acoustic attenuation of the human tissue, is nontoxic, durable and easy to handle and maintain. Comparable and reproducible results can be achieved from a single image, making this a perfect daily QA tool. To determine the spatial resolution of phantom images, a modulation transfer function (MTF) is calculated by the Diagnomatic software using radial MTF algorithm. In addition radial MTF test object the phantom also contains structures for geometry assessment.
Benefits
Technical data:
Overal dimensions: 110 x 110 x 60 mm
Top and bottom cover made of PCV
Test insert dimensions: 110 x 110 x 50 mm
Test insert contains:
- 20 mm in diameter round object (20 mm and 10 mm from phantom faces) for radial MTF
- 2 groups of four round rods (1 mm in diameter) with 15 mm horizontal and vertical spacing for geometry assessmenttTssue mimicking material is based on Polyvinyl alcohol (PVA), a synthetic polymer
Carrying case
Product features:
Complies with:
– “Quality Assurance for Ultrasound Scanners usinga durable tissue-mimicking Phantom and radial MTF”, Marcus Kaar, Friedrich Semturs, Michael Figl, Rainer Hoffmann1 and Johann Hummel, Center for Biomedical Engineering and Physics, Medical University of Vienna, Austria
– Real-time B-mode US quality control test procedures: Report of AAPM Task Group No. 1
– Quality assurance of U.S. - guided external beam radiotherapy for prostate cancer: Report of AAPM Task Group 154CE marked
The manual provides detailed guidelines for carrying out each test, results assessment and registration
Let's Talk
Have a question, need a quote, or want to book a demo? We’re here to help.
info@meditron.ch
+41 22 995 01 91
Place de l'Industrie 2, 1180 Rolle Schönenhofstrasse 19, 8500 Frauenfeld

Pro-US MTF
Ultrasound
Diagnomatic
The tissue-mimicking phantom for use in routine technical quality assurance (TQA). The PVA based material mimics the sound velocity and acoustic attenuation of the human tissue, is nontoxic, durable and easy to handle and maintain. Comparable and reproducible results can be achieved from a single image, making this a perfect daily QA tool. To determine the spatial resolution of phantom images, a modulation transfer function (MTF) is calculated by the Diagnomatic software using radial MTF algorithm. In addition radial MTF test object the phantom also contains structures for geometry assessment.
Benefits
Technical data:
Overal dimensions: 110 x 110 x 60 mm
Top and bottom cover made of PCV
Test insert dimensions: 110 x 110 x 50 mm
Test insert contains:
- 20 mm in diameter round object (20 mm and 10 mm from phantom faces) for radial MTF
- 2 groups of four round rods (1 mm in diameter) with 15 mm horizontal and vertical spacing for geometry assessmenttTssue mimicking material is based on Polyvinyl alcohol (PVA), a synthetic polymer
Carrying case
Product features:
Complies with:
– “Quality Assurance for Ultrasound Scanners usinga durable tissue-mimicking Phantom and radial MTF”, Marcus Kaar, Friedrich Semturs, Michael Figl, Rainer Hoffmann1 and Johann Hummel, Center for Biomedical Engineering and Physics, Medical University of Vienna, Austria
– Real-time B-mode US quality control test procedures: Report of AAPM Task Group No. 1
– Quality assurance of U.S. - guided external beam radiotherapy for prostate cancer: Report of AAPM Task Group 154CE marked
The manual provides detailed guidelines for carrying out each test, results assessment and registration